If you are having problems printing this page, hit Ctrl-P to print.
Added Low Hydrogen Designators Don't Change Electrodes
by Dennis Hartman, Consumables Research and Development, The Lincoln Electric Company, Cleveland, Ohio
Welders accustomed
to using a low-hydrogen electrode with a particular classification
are sometimes puzzled when they receive electrodes with added designations
like H4R. Low-hydrogen electrodes are generally used in more critical
applications to begin with, and their concern is understandable.
However, its simply a case of the manufacturer providing more information
on the same electrode as before.
The added characters are optional designators, permitted by the AWS classification system, to clarify the low-hydrogen characteristics of carbon steel and low alloy steel manual electrodes. Nothing in the electrodes themselves has changed.
Low hydrogen is defined as less than 16 milliliters (ml.) per 100 grams of weld metal. This classification has now been stratified into three levels, so the added designators make it easier to quickly determine how dry a particular electrode is. The levels are H16, H8, and H4, corresponding to 16, 8, and 4 ml. per 100 grams of weld metal. These represent the maximum diffusible hydrogen levels obtainable with a specific product.
One additional
designator may also be added. This is an optional moisture resistant
designator (R), which indicates a low-hydrogen electrodes ability
to meet specific low-moisture pickup limits under controlled humidification
tests. This generally indicates that the electrodes coating has
been formulated with non-hygroscopic materials and will resist
picking up moisture longer than electrodes with standard low-hydrogen
coatings. This can be important when welding in humid areas, since
a standard coating will be affected by moisture in about two hours,
while a moisture-resistant coating can be safe to use for as long
as 10 hours.
When these suffixes are used, they must be imprinted on the electrode itself, in addition to appearing on the label. The actual AWS classification does not change when they are added, however. For example, an E7018 H4R product will still be classified as E7018, although the product is identified by the full designation.
With any low-hydrogen consumable, it is important to observe proper storage procedures. Products such as the H4 electrodes come in a hermetically sealed can. Once opened, they should be stored in a rod oven until used, since they may not meet specifications if left open in high humidity. In case of doubt about low-hydrogen electrodes and their application, the supplier should be consulted for recommendations.