Fleetweld 5P 14 Stick Electrode in 10 lb cans"

Diámetros / Embalaje

Diámetros
mm
8 lb (3.6 kg) Easy Open Can
10 lb (4.5 kg) Easy Open Can
1/8 x 14 in (3.2 x 350 mm) ED033094
3/16 x 14 in (4.8 x 350 mm) ED033096
3/32 x 12 in (2.4 x 300 mm) ED033097
5/32 x 14 in (4.0 x 350 mm) ED033095

Excalibur® 309/309L-16

Soldadura de Arco Metálico Protegido (SMAW) | ED033096

CLASIFICACIONES:
E309-16
E309L-16

Excalibur 309/309L-16 brinda una cubierta de fundente que proporciona una transferencia suave de arco para todas las posiciones de soldadura excepto la vertical hacia abajo, diseñado para unir acero inoxidable a acero dulce o de baja aleación.

Detalles

EXCALIBUR® 309/309L-16 has a flux coating that produces smooth arc transfer during welding.

Características

  • Electrode coating provides smooth arc transfer in all welding positions, except vertical down
  • Q2 Lot® - Certificate showing actual deposit composition and ferrite number (FN) by ferrite scope available online

Servicio de información

También puede necesitar

ANTES DE USARLO, LEA Y COMPRENDA LA HOJA DE DATOS DE SEGURIDAD (SDS) DE ESTE PRODUCTO Y LA INFORMACIÓN ESPECÍFICA IMPRESA EN EL ENVASE DEL PRODUCTO. Página de Búsqueda SDS

Ver los resultados de la prueba de limitación de responsabilidad

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.4 E309-16, E309L-16
ABS AWS A5.4 E309-16, E309L-16
CWB CSA W48 E309-16, E309L-16

MECHANICAL PROPERTIES

Classification Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
E309-16 Requirement 550 (80) min. 30 min.
E309L-16 Requirement 520 (75) min. 30 min.
Typical Result, As-welded 470-490 (68-71) 600-610 (87-88) 32-42

DEPOSIT COMPOSITION

Classification %Bi %C %Cr %Cu %Mn %Mo %N %Ni %P %S %Si Ferrite Number (per AWS A4.2)
E309-16 Requirement 0.15 max. 22.0 - 25.0 0.75 max. 0.5 - 2.5 0.75 max. 12.0 - 14.0 0.04 max. 0.03 max. 1.00 max.
E309L-16 Requirement 0.04 max. 22.0 - 25.0 0.75 max. 0.5 - 2.5 0.75 max. 12.0 - 14.0 0.04 max. 0.03 max. 1.00 max.
Typical Result 0.001 0.03-0.04 23.8-24.6 0.04-0.08 1.4-1.7 0.08-0.40 0.06-0.10 12.7-13.4 0.02-0.03 0.01-0.02 0.36-0.55 9-16

TYPICAL OPERATING PROCEDURES

Diameter Polarity⁽¹⁾ Current
Amps
3/32 in (2.4 mm) DC+ 40-70
3/32 in (2.4 mm) AC 40-70
1/8 in (3.2 mm) DC+ 60-100
1/8 in (3.2 mm) AC 60-100
5/32 in (4.0 mm) DC+ 90-140
5/32 in (4.0 mm) AC 90-140
3/16 in (4.8 mm) DC+ 120-185
3/16 in (4.8 mm) AC 120-185

NOTES

Note
⁽¹⁾ Preferred polarity is listed first.